DIP Switch
|
Number |
Function |
Description |
|
1 |
Slow Start Function |
OFF-enable; ON-disable. Default OFF |
|
2 |
Limit Mode Switching |
OFF-normally open limit; ON-normally closed limit. Default OFF, used with motor limit status, not recommended to be modified by the user |
|
3
|
Automatic Close Time |
Automatic close time setting: the gate is operated to open by remote control operation and will close automatically after a few seconds delay. 3 OFF 4 ON: automatic close delay time is 12s. 3 ON 4 OFF: automatic close delay time is 24s. 3 ON 4 ON: automatic close delay time is 36s. 3 OFF 4 OFF: no automatic close function. Default setting: 3 OFF 4 OFF Disable the automatic close function. |
|
4
|
||
|
5 |
Auto-reverse Function |
OFF-enable ON-disable Default position is OFF, this should align with the opener status and is not recommended to be modified by the users. |
|
6 |
Remote Channel |
OFF - Single channel ON - Three channels |
Potentiometer Adjustment
All changes to these settings must be completed by a licensed electrician.

VR1: Stall Force Mode
Maximum = More Force = Less sensitive
Minimum = Less Force = More sensitive
When Stall Force Mode is enabled (Dip switch 5 is at OFF position), the gate opener will detect obstacles and impacts to the gate. If this is during opening, the gate will stop, if this is during closing the gate will stop, and then re-open. Rotate VR1 clockwise to increase the stall force, anti-clockwise to decrease.
For safety, we strongly recommend that Stall Force Mode is left enabled (Dip switch 5 is at the OFF position). Do not turn Dip switch 5 to the ON position.
VR2: Brake Force Adjustment
For adjusting brake force at the limit position during gate opening and closing. This should only be adjusted for heavy gates that need additional force to brake when limit switch is detected.
Rotate VR2 clockwise to increase, counter-clockwise to decrease. Default setting is at minimum.
VR3: Slow Stop Width Adjustment
This switch controls how many seconds the gate opener operates at maximum speed. Rotate VR3 clockwise to increase, rotate counter-clockwise to reduce.
When VR3 switches to minimum, slow start/stop function is disable.
VR4: Motor Output Force Adjustment
For best performance, set the torque at the lowest setting for secure use.
Rotate clockwise to increase, counter-clockwise to decrease.
Default setting is at maximum.
Terminal Instructions
J1 Terminal
PE: Earth (yellow/green wire).
L: Power (brown wire).
N: Power (blue wire).
J2 Terminal
MOT1: Motor Terminal, swap with MOT2 to change gate moving direction.
MOT2: Motor Terminal, swap with MOT1 to change gate moving direction.
MOTCOM: Motor Common Terminal.
LAMP (L&N): Connection for warning lamp.
PE: Motor and warning lamp earth
Note: If require to change the moving direction, not only MOT1 and MOT2 wires need to be swapped, but also the wires of 10 and 12 on J5 Terminal have to be swapped with each other.
J3 Terminal
Motor Capacitor
J6 Terminal: Port 13 and Port 14 output door closing in place feedback signals.
J5Terminal: Limit Switch and Accessories
Additional accessories sold separately
Port 12:Open Limit Switch
Port 11:Limit Switch Common Port
Port 10:Close Limit Switch
Port 9:Ground/Earth (GND)
Port 8:Photocell input (N.C.). If no photocell is fitted, use a jumper between Ports 8 & 9.
Port 7:Power supply for accessories (+15V)
J4 Terminal: (as per Figure 18)
Port 6: External Push Button Pedestrian Switch.
Port 5: External button Single cycle button. (Cycle open/stop/close)
Port 4:Common Port for All External Control Push Button
Port 3:External Stop Push Button Switch.
Port 2:External Open Push Button Switch.
Port 1:External Close Push Button Switch.
Hot Tags: gasl500ac(ac sliding motor control board), China gasl500ac(ac sliding motor control board) manufacturers, suppliers, factory, YS422-66, PY600 MLA AC Sliding Motor Control Board , GASL800DC DC Sliding Motor Control Board , RT18 Wireless Keypad, 0 5m Galvanized Gear Rack, RT82