PY600-AZJ(AC Sliding Motor Control Board)

PY600-AZJ(AC Sliding Motor Control Board)
Details:
Power supply:110VAC/60Hz; 220VAC/50Hz
Soft start&Slow stop
Auto reverse function (need hall sensor) Auto close ;Pedestrian Mode
Support Photo sensor;Lamp;Extra button
Send Inquiry
Description

AC Sliding Motor Control Board(PY600-AZJ)

 
 

 

Power supply:110VAC/60Hz; 220VAC/50Hz

Soft start&Slow stop

Auto reverse function (need hall sensor) Auto close ;Pedestrian Mode

Support Photo sensor;Lamp;Extra button

 

DIP Switch

 

 

Number

Function

Description

1

Soft Start/Close Function

OFF–enabled

ON–disabled

Default position is OFF.

2

Limit Switch Setting

OFF–Normal Open

ON–Normal Close

Default position is OFF, this should align with limit switch and is not recommended to be modified by the users.

3

 

Automatic Close Time Setting

Automatic close time setting: the gate is operated to open by remote control operation and will close automatically after a few seconds delay.

3 OFF 4 ON: automatic close delay time is 12s.

3 ON 4 OFF: automatic close delay time is 24s.

3 ON 4 ON: automatic close delay time is 36s.

3 OFF 4 OFF: no automatic close function.

Default setting: 3 OFF 4 OFF

Disable the automatic close function.

4

 

5

Auto-reverse Function

OFF-enable

ON-disable

Default position is OFF, this should align with the opener status and is not recommended to be modified by the users.

6

(optional)

External button switch mode setting

ON - External button switch is four button mode.

OFF - External button switch is single button mode.

(optional):If your control board only has five dials, it is invalid.

 

Potentiometer Adjustment

 

 

product-623-211

 

VR1: Stall Force Mode

Maximum = More Force = Less sensitive

Minimum = Less Force = More sensitive

 

When Stall Force Mode is enabled (Dip switch 5 is at OFF position), the gate opener will detect obstacles and impacts to the gate. If this is during opening, the gate will stop, if this is during closing the gate will stop, and then re-open. Rotate VR1 clockwise to increase the stall force, anti-clockwise to decrease.

 

For safety, we strongly recommend that Stall Force Mode is left enabled (Dip switch 5 is at the OFF position). Do not turn Dip switch 5 to the ON position.

 

VR2: Brake Force Adjustment

For adjusting brake force at the limit position during gate opening and closing. This should only be adjusted for heavy gates that need additional force to brake when limit switch is detected.

Rotate VR2 clockwise to increase, counter-clockwise to decrease. Default setting is at minimum.

 

VR3: Slow Start/Stop Width Adjustment

This switch controls how many seconds the gate opener operates at maximum speed. Rotate VR3 clockwise to increase, rotate counter-clockwise to reduce.

When VR3 switches to minimum, slow start/stop function is disable.

 

VR4: Motor Output Force Adjustment

For best performance, set the torque at the lowest setting for secure use.

Rotate clockwise to increase, counter-clockwise to decrease.

Default setting is at maximum.

 

Terminal Instructions

 

 

J2 Terminal (as per Figure 15):

Terminal 6: External Push Button Pedestrian Switch

Terminal 5: External Open/Stop/Close/Stop Loop Control Push Button (Repeated Open/Stop/Close)

Terminal 4: Common Terminal for All External Control Push Button

Terminal 3: External Stop Push Button Switch.

Terminal 2: External Open Push Button Switch.

Terminal 1: External Close Push Button Switch.

 

J5 Terminal: Limit Switch and Accessories

Additional accessories sold separately

 

Terminal 13: Open Limit Switch

Terminal 12: Limit Switch Common Terminal

Terminal 11: Close Limit Switch

Terminal 10: Loop Detector Connector (Pre-wired by Factory)

Terminal 9: Ground/Earth (GND)

Terminal 8: Photocell input (N.C.). If no photocell is fitted, use a jumper between terminals 8 & 9.

Terminal 7: Power supply for accessories (+15V)

 

J6 Terminal:

Motor Capacitor

 

J4 Terminal:

MOT1: Motor Terminal, swap with MOT2 to change gate moving direction.

MOT2: Motor Terminal, swap with MOT1 to change gate moving direction.

MOTCOM: Motor Common Terminal.

LAMP (L&N): Connection for warning lamp.

PE: Motor and warning lamp earth

Note: If require to change the moving direction, not only MOT1 and MOT2 wires need to be swapped, but also the wires of 11 and 13 on J5 Terminal have to be swapped with each other.

 

J3 Terminal:

PE: Earth (yellow/green wire).

L: Power (brown wire).

N: Power (blue wire).

Hot Tags: py600-azj(ac sliding motor control board), China py600-azj(ac sliding motor control board) manufacturers, suppliers, factory, Outdoor Button Switch, PB03 External Button Switch, RT36, RT54, RT77, Solar Charger